Browse all practice questions for the Florida Journeyman Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Florida Journeyman Practice Exam course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What would disallow duct from penetrating a third floor without a fire damper?
  • What can appliance vent connectors and joints be securely joined with?
  • Residential gas furnaces may be vented with single wall vent piping under all conditions except?
  • What should be used to cover air inlets from outside the building serving residential occupancies?
  • Which type of lighting should be used in damp environments?
  • Why must liquid and suction line piping be sized large enough?
  • What is a typical sign of a starved evaporator?
  • What color identifies a grounded conductor in electrical wiring?
  • What is the minimum level of insulation required for a portion of supply duct greater than 3 inches in diameter on the exterior of a residential structure?
  • Which statement about hearing protection for employees is true?
  • Which substance should not be used for safety reasons within a refrigerant system for testing?
  • Which of these tapes is acceptable as a closure system for fibrous glass duct board?
  • What is the purpose of using an anemometer in refrigeration systems?
  • What is the main advantage of using LED lighting?
  • What is an ampere?
  • A thermostat is a device that detects what condition?
  • What does adjusting the superheat primarily affect in a refrigeration system?
  • Which of these tapes is acceptable as a closure system for fibrous glass ductboard?
  • What type of device protects sensitive electronics from power surges?
  • What is the residential service voltage in most Florida homes?
  • Where should the main burner of a gas-fired boiler have an approved manual shut-off valve installed?
  • How many ohms is considered a low-resistance connection?
  • Why is it important to label circuit breakers in an electrical panel?
  • What is the minimum number of hours required for Journeyman Electrical Apprenticeship in Florida?
  • What kind of ground is typically used for electrical devices in wet locations?
  • What should be the maximum number of lighting fixtures connected to a 20-amp circuit?
  • An emergency refrigeration control switch is required to shut off all electrically operated machinery in what type of room?
  • What size wire is typically used for a 30-amp circuit?
  • What is the difference between series and parallel circuits?
  • Copper tubing used for refrigerant piping of mechanical refrigeration systems shall be commercially designated as?
  • Which factors influence the selection of wire sizes in electrical installations?
  • What type of wire is typically used for residential wiring?
  • What type of equipment operates by cooling through the evaporation of water into the air system?
  • What does a wattmeter measure?
  • What is the function of a fuse in an electrical system?
  • What is the standard height for light switches in residential buildings?
  • What type of ventilating equipment can be transported easily without dismantling and is not connected to a duct?
  • What is the primary function of circuit breakers in electrical systems?
  • What is the minimum width of a discharge opening for a grease duct serving a type one hood?
  • Why is it important to maintain proper distances from exhaust discharges in machinery rooms?
  • If an appliance is installed to its listed clearance, what will the installation be considered?
  • What is the maximum outlet temperature limit for warm air in a plenum supplied by a furnace?
  • Which of the following is not a requirement for air dispersion system?
  • Which of the following is not a requirement for an air dispersion system?
  • What is the maximum height of a surface that an employee can work or walk above an adjoining?
  • In a medium temperature application, how can heat transfer resistance in the evaporator be reduced?
  • What is the normal procedure for checking electrical circuits?
  • Drainage and overflow from cooling towers and evaporated condensers may discharge into which of these areas?
  • Which of the following shall not be used for safety reasons within a refrigerant system for testing?
  • What is required for every electrical service according to Florida code?
  • What is the maximum height for outdoor lighting installations?
  • If a user finds that their refrigerant system is oversaturated, what is a likely contributing factor?
  • For safety reasons, which gas should not be used for testing refrigerant systems?
  • What is typically used to limit the amount of current flowing in a circuit?
  • What is the minimum thickness required for a 14" round sheet metal duct used in a residence?
  • Condensate drain piping shall not be installed with a slope of less than?
  • What impact does reducing the airflow across the evaporator have on the system?
  • In a ducted system with a cooling coil installed and an existing furnace heat exchanger, where must the air first flow through according to code?
  • What code must all new electrical installations comply with?
  • How does a contactor operate?
  • Which of the following is prohibited for mechanical refrigerating systems and portions thereof?
  • What is the minimum clearance required for overhead service wires over residential properties?
  • What does NEC stand for in the context of electrical standards?
  • What is the safe distance for installing outdoor electrical wiring above the ground?
  • In a medium temperature application, the major resistance to heat transfer in the evaporator is the film of refrigerant oil. How may this be reduced?
  • What is a common effect of high pressure in the high side of a refrigeration system?
  • Which code specifies the standards for ventilation supply air?
  • What is an electrical discharge?
  • All of the following are indications of partial restriction on high side except?
  • Condensate drain piping shall not be installed with a slope of less than?
  • Which device is most commonly used for protecting against electrical shocks in wet environments?
  • What is the maximum distance between outlets in a residential kitchen according to the NEC?
  • What happens if the testing gas is not properly removed from a refrigerant system?
  • In a machinery room containing mechanical refrigerating equipment, what is the minimum distance required between the machinery room exhaust discharge and the exterior door or window?
  • Which valve is used to control the gas supply to the burners during operation of an appliance?
  • What is the purpose of a transformer?
  • Where must a platform be provided for equipment in an attic installation?
  • Boilers shall be tested for carbon monoxide to what maximum level?
  • To check electrical circuits, how is a voltmeter usually connected?
  • What is the primary function of a transformer?
  • When installing receptacles, what is the required height from the floor?
  • What is the purpose of a surge protective device?
  • For what purpose is a main disconnect switch installed in an electrical service?
  • What is the main purpose of a circuit breaker?
  • Which gas is commonly used for pressure testing refrigerant systems due to its safety?
  • A duct serving a type one grease hood that penetrates a ceiling, wall, or floor should be enclosed in a duct enclosure from which point?
  • What type of exhaust is approved for connection to a 6" flue stack venting a gas-fired furnace?
  • Which of the following is not a main type of automatic refrigerant flow control?
  • How high should the pan of batten seam roofs be turned?
  • A vertical duct delivers outside combustion air to a water heater. What is the minimum area of each duct if the water heater is rated at 45,000 btuh?
  • An emergency refrigeration controls switch shall be provided to shut off all electrically operated machinery in any machinery room containing a mechanical refrigeration system. What may the switch not shut off?
  • How many circuits can be placed on a 20-amp breaker in a residential setting?
  • What is the primary function of a receiver in a refrigerant system?
  • What is the function of a relay in an electrical circuit?
  • The minimum spacing between rungs, cleats, or steps of a fixed ladder on a construction site shall be?
  • What is the minimum unobstructed access width that must be provided on all sides of a boiler?
  • In refrigerant systems, which system component governs the rate of refrigerant flow?
  • The components of a refrigeration system under evaporator pressure are referred to as what?
  • Which procedure is crucial before performing maintenance on a refrigeration system?
  • What electrical code section deals specifically with residential wiring?
  • Which Florida agency oversees licensing for electrical contractors?
  • What is required for every automatic hot water heating boiler not under continuous attendance?
  • What should be considered when installing outdoor wiring?
  • What is the outside sheet metal size of an insulated duct with an airside dimension of 18"x10" and 1" insulation?
  • A boiler furnishing steam air pressures in excess of 15 psi is classified as what?
  • What is the primary purpose of grounding in electrical systems?
  • What type of space is indirectly cooled and enclosed within the building's thermal envelope?
  • What is the minimum clearance from a grease duct system to combustible material?
  • Which of the following is not acceptable material for the base of a boiler?
  • Which of the following is not a main type of automatic refrigeration flow control?
  • What type of pressure does an evaporator usually operate under?
  • What is the minimum spacing between rung cleats or steps of a fixed ladder at a construction site?
  • What is the primary purpose of a ventilation system in a commercial kitchen?
  • What type of labeling is required on refrigerant pressure relief devices?
  • What is the minimum clearance to combustible materials for a duct system operating between 125 degrees and 250 degrees?
  • When are junction boxes required in residential wiring?
  • Gas equipment is installed on a roof 4 feet from the edge of the roof, how high must the railing be?
  • What could be caused by high head pressure in a refrigerant system?
  • What is the minimum thickness needed for a 14-inch round sheet metal duct used in a residence?
  • What should be monitored to ensure safe operation of gas-fired boilers?
  • What is the primary material used for electrical panel grounding?
  • What electrical hazard is caused by aging wiring or insulation?
  • What is the minimum area for vertical ducts delivering outside combustion air to a 45,000 BTU/h rated water heater?
  • Which of the following factors is NOT a consideration in ventilation systems?
  • What is an acceptable method for scavenging the combustion chamber and breaching of a boiler?
  • What is the purpose of the bleed port in a thermostatic expansion valve?
  • What instrument is used to measure airflow velocity?
  • Which of the following is not a type of electrical wiring?
  • Absorption systems use which type of refrigerant for better efficiency in certain conditions?
  • Which material is most commonly used for electrical conduit?
  • What is the minimum ampacity requirement for home branch circuits?
  • What is the purpose of a disconnect switch?
  • An outside air inlet for a non-residential portion of a building can have a screen with openings but must be smaller than what size?
  • Which of the following is a primary function of an air handling unit in ventilation systems?
  • What happens to the evaporator if a thermostatic expansion valve is oversized for a system?
  • When an appliance with a combustible chamber is located in the same room as a ventilation system return air opening, how close should the return air be to the open combustion?
  • When removing any group 1 refrigerant except CO2 from a refrigeration system, how should it be discharged?
  • What does GFCI stand for in electrical systems?
  • Which type of duct is typically used for exhaust purposes in commercial kitchens?
  • Which component is typically used to interrupt power in an electrical service?
  • An outside air inlet serving a nonresidential portion of a building may be covered with a screen. The size of the opening in this screen mesh must be no smaller than what size?
  • In refrigerant systems, excessive nitrogen can lead to which condition?
  • A refrigerant system that has been improperly pressure-tested could lead to what type of operational issue?
  • What is the primary function of a thermostatic expansion valve in a refrigerant system?
  • According to regulations, the return air from a dwelling unit shall not be discharged through the cooling system to what?
  • What does a voltmeter measure?
  • What is the rated lifespan for most incandescent light bulbs?
  • How often must a residential electrical panel be inspected?
  • What is the primary role of a surge protector?
  • What must all closed type hot water heating systems, not under continuous attendance, be provided with?
  • Where shall the main burner of a gas fired boiler have an approved manual shut off valve installed?
  • What type of screen is required for air inlets from outside the building serving residential occupancies?
  • In an attic installation, where must a platform be provided?
  • Where must smoke alarms be installed in a home?
  • What does the term "ampacity" refer to?
  • What is the main benefit of a low water cutoff switch for a boiler?
  • If a compressor has a displacement of 10 cubic inches but actually pumps 6 cubic inches, what is its volumetric efficiency?
  • What must every fuel-burning heating appliance bear on a permanent and legible factory-applied nameplate?
  • What type of device uses a RCD to prevent electrical shock?
  • In what conditions can electricians work on energized circuits?
  • What is the function of a grounding electrode system?
  • What is an established and recognized agency called that is engaged in conducting tests or furnishing inspection services?
  • What is the minimum clearance required to combustibles for duct systems operating between 125°F and 250°F?
  • What is a sign of a faulty transformer in an electrical circuit?
  • Which of the following is not a requirement for a fire damper?
  • What does the term "conductor" mean in electrical terms?
  • What is the maximum allowable voltage drop for branch circuits?
  • What is a common indication of electrical overload?
  • Insulation applied to an exterior surface of ducts in buildings other than dwelling or apartments shall have a flame spread rating of not more than?
  • What size breaker is required for a 12-gauge copper wire?
  • What is the flame spread rating limit for insulation applied to ducts in buildings other than dwellings or apartments?
  • Which of the following is not acceptable material for the base of a boiler?
  • Which factor is not considered in ventilation systems?
  • Absorption refrigerating systems must not be located less than 20 feet from a door window or ventilating air inlet to any building unless what condition is met?
  • Combustion air supply is required for which type of equipment?
  • What is the first procedure to perform when starting up a new unit?
  • What is the purpose of bonding in electrical systems?
  • Which issues might originate from a compressor operating at reduced volumetric efficiency?
  • What is the purpose of a ground fault circuit interrupter (GFCI)?
  • What defines a "dedicated circuit"?
  • What does the term "overcurrent" mean?
  • According to NEC, how many receptacles are permitted per 20-amp circuit?
  • What is the most serious consequence of not removing all the nitrogen used for pressure testing on an HCFC system?
  • What is the required depth for underground electrical service conductors?
  • What effect does a thermostatic expansion valve with a discharge power element have on the evaporator?
  • What is the minimum thickness required for Type I commercial hoods made of stainless steel?
  • An established and recognized agency regularly engaged in conducting tests of furnishing inspection services when such agency has been approved by the building official is called?